  1.                          SECTION 15083
  2.  
  3.                   15083 - PIPING SAFETY COVERS
  4. NOTE ** Truebro, Inc. piping safety covers and undersink
  5.         enclosures for lavatories and sinks.
  6. NOTE **
  7. NOTE ** This section is based on products manufactured by
  8.         Truebro, Inc., located at the following address:
  9. NOTE **     7 Main Street
  10. NOTE **     P.O. Box 440
  11. NOTE **     Ellington CT 06029
  12. NOTE **     Tel:  (800) 340-5969 outside CT
  13. NOTE **     Tel:  (860) 875-2868 inside CT
  14. NOTE **     Fax:  (860) 872-0300
  15. NOTE **     Email:  truebro@tiac.net
  16. NOTE **     Internet:  http://www.truebro.com
  17. NOTE **
  18. NOTE ** Truebro, Inc. offers ADA-compliant piping piping
  19.         safety covers for virtually all hot water supply
  20.         and waste piping configurations, as well as
  21.         undersink enclosures for ADA-compliant lavatories
  22.         and sinks.
  23. NOTE **
  24. NOTE ** SECTION 15083 - PIPING SAFETY COVERS, Copyright
  25.         1997, The Architect's Catalog, Inc.
  26.  
  27.  
  28. PART 1  GENERAL
  29.  
  30. 1.1 SECTION INCLUDES
  31. NOTE ** Delete items below not required for project.
  32.  
  33.     A.  Piping Safety Covers.
  34.  
  35.     B.  Lavatory Piping Enclosure.
  36.  
  37.     C.  Basin/Sink Piping Enclosure.
  38.  
  39. 1.2 RELATED SECTIONS
  40. NOTE ** Delete any sections below not relevant to this
  41.         project; add others as required.
  42.  
  43.     A.  Section 15082 - Piping Insulation.
  44.  
  45.     B.  Section 15145 - Plumbing Piping.
  46.  
  47. 1.3 REFERENCES
  48. NOTE ** Delete references from the list below that are not
  49.         actually required by the text of the edited
  50.         section.
  51.  
  52.     A.  ASTM C 177 - Standard Test Method for Steady-State Heat
  53.         Flux Measurements and Thermal Transmission Properties by
  54.         Means of the Guarded-Hot-Plate Apparatus.
  55.  
  56.     B.  ASTM D 635 - Standard Test Method for Rate of Burning
  57.         and/or Extent and Time of Burning of Self-Supporting
  58.         Plastics in a Horizontal Position.
  59.  
  60.     C.  ASTM D 2240 - Standard Test Method for Rubber Property -
  61.         Durometer Hardness.
  62.  
  63.     D.  CABO/ANSI A117.1 - American National Standard for
  64.         Buildings and Facilities - Providing Accessible and
  65.         Usable Buildings and Facilities.
  66.  
  67.     E.  UL 94 - Test for Flammability of Plastic Materials for
  68.         Parts in Devices and Appliances.
  69.  
  70. 1.4 SYSTEM DESCRIPTION
  71.  
  72.     A.  Design Requirements:  Products of this section to conform
  73.         to the following:
  74.         1.  Americans With Disabilities Act (ADA), Article
  75.             4.19.4.
  76.         2.  CABO/ANSI A117.1.
  77.         3.  Requirements of regulating building code.
  78.  
  79. 1.5 SUBMITTALS
  80.  
  81.     A.  Submit under provisions of Section 01300.
  82.  
  83.     B.  Product Data:  Manufacturer's descriptive literature for
  84.         products specified in this section.
  85. NOTE ** Delete the following paragraph if specifying Lav-
  86.         Shield or Basin Guard only.
  87.  
  88.     C.  Shop Drawings:  Indicate locations and configurations of
  89.         piping insulation for indicated plumbing configurations.
  90.  
  91.     D.  Quality Assurance Submittals:  Manufacturer's printed
  92.         installation instructions for each specified product.
  93.  
  94. 1.6 DELIVERY, STORAGE, AND HANDLING
  95.  
  96.     A.  Store products of this section in manufacturer's unopened
  97.         packaging until installation.
  98.  
  99.  
  100. PART 2  PRODUCTS
  101.  
  102. 2.1 MANUFACTURERS
  103.  
  104.     A.  Acceptable Manufacturer:  Truebro, Inc.; 7 Main Street,
  105.         P.O. Box 440, Ellington CT 06029; ASD. Tel. (800) 340-
  106.         5969 (outside CT), (860) 875-2868 (inside CT); Fax (860)
  107.         872-0300; Email truebro@tiac.net; Internet
  108.         http://www.truebro.com
  109. NOTE ** Delete one of the two following paragraphs;
  110.         coordinate with Division 1 requirements.
  111.  
  112.     B.  Requests for substitution will be considered in
  113.         accordance with provisions of Section 01600.
  114.  
  115.     C.  Substitutions:  Not permitted.
  116.  
  117. 2.2 PIPING INSULATION
  118. NOTE ** Lav-Guard components will fit all 1-1/4 inch (32
  119.         mm) and 1-1/2 inch (38 mm) diameter cast brass or
  120.         tubular waste piping components and all 3/8 inch (9
  121.         mm) and 1/2 inch (12 mm) diameter supply piping
  122.         components; they will not fit Schedule 40 plastic P-
  123.         traps.
  124.  
  125.     A.  Piping Safety Covers:
  126.         1.  Acceptable products:  Truebro Lav-Guard.
  127.         2.  Characteristics:  One-piece vinyl components, minimum
  128.             1/8 inch (3 mm) wall thickness, with internal ribs to
  129.             provide air space between piping and piping
  130.             insulation jacket, molded to receive manufacturer's
  131.             snap-clip fasteners.
  132.         3.  Vinyl material:  Impact-resistant and stain-resistant
  133.             molded closed-cell anti-microbial vinyl compound, UV-
  134.             stable, non-fading, non-yellowing: having the
  135.             following performance characteristics:
  136.             a.  Burning characteristics, when tested in
  137.                 accordance with ASTM D 635:  0 seconds Average
  138.                 Time of Burning (ATB), 0 mm Area of Burning
  139.                 (AEB).
  140.             b.  Thermal conductivity, when tested in accordance
  141.                 with ASTM C 177:  K-value 1.17 (2.02 metric
  142.                 equivalent).
  143.             c.  Indentation hardness, when tested in accordance
  144.                 with ASTM D 2240:  60 Shore A, minimum.
  145.         4.  Trap assembly cover:  Three-piece assembly, with
  146.             removable clean-out nut enclosure.
  147.         5.  Angle stop covers:  Formed with hinged cap for access
  148.             to valve without requiring cover removal.
  149.         6.  Configurations:  In accordance with manufacturer's
  150.             product data for project piping configurations
  151.             indicated on drawings.
  152. NOTE ** Select vinyl finish color in one of the following
  153.         two sub-paragraphs.
  154.         7.  Color:  China White, gloss finish; paintable.
  155.         8.  Color:  Light Gray, gloss finish.
  156.  
  157.     B.  Fasteners:  Manufacturer's standard re-usable snap-clip
  158.         fasteners; wire-tie fasteners not permitted.
  159.  
  160. 2.3 LAVATORY PIPING ENCLOSURE
  161. NOTE ** Lav-Shield will fit all ADA-compliant 20-inch (508
  162.         mm) by 18-inch (457 mm) wall-hung china lavatories.
  163.     A.  Lavatory Piping Enclosure:
  164.         1.  Acceptable product:  Truebro Lav-Shield.
  165.         2.  Characteristics:  One-piece rigid molded vinyl
  166.             enclosure, minimum 1/8 inch (3 mm) wall thickness,
  167.             factory-punched for manufacturer's wall fasteners.
  168.         3.  Vinyl material:  Impact-resistant and stain-resistant
  169.             molded closed-cell vinyl, having the following
  170.             performance characteristics:
  171.             a.  Burning characteristics, when tested in
  172.                 accordance with ASTM D 635:  0 seconds Average
  173.                 Time of Burning (ATB), 0 mm Area of Burning
  174.                 (AEB).
  175.             b.  Flammability:  UL 94 V-O rating.
  176.             c.  Indentation hardness, when tested in accordance
  177.                 with ASTM D 2240:  69 Shore D, minimum.
  178.         4.  Vinyl color:  China White, fine-textured finish;
  179.             paintable.
  180. NOTE ** Retain one of the following two paragraphs.
  181.  
  182.     B.  Fasteners:  Manufacturer's standard stainless steel wall
  183.         fasteners.
  184.  
  185.     C.  Fasteners:  Manufacturer's standard stainless steel wall
  186.         fasteners with tamper-resistant heads.
  187.  
  188. 2.4 BASIN/SINK PIPING ENCLOSURE
  189. NOTE ** Basin Guard will fit all ADA-compliant sinks and
  190.         lavatories installed in countertops, below
  191.         countertops between cabinets or walls; 36-inch (914
  192.         mm) and 42-inch (1066 mm) widths available.
  193.     A.  Basin Piping Enclosure:
  194.         1.  Acceptable product:  Truebro Basin Guard.
  195.         2.  Characteristics:  One-piece rigid molded vinyl
  196.             enclosure, minimum 0.093 inch (2.3 mm) wall
  197.             thickness, factory-punched flanges for fasteners.
  198.         3.  Vinyl material:  Impact-resistant and stain-resistant
  199.             molded closed-cell vinyl, having the following
  200.             performance characteristics:
  201.             a.  Burning characteristics, when tested in
  202.                 accordance with ASTM D 635:  0 seconds Average
  203.                 Time of Burning (ATB), 0 mm Area of Burning
  204.                 (AEB).
  205.             b.  Boca Basic Building Code Fire Rating:  Class 1.
  206.             c.  Indentation hardness, when tested in accordance
  207.                 with ASTM D 2240:  69 Shore D, minimum.
  208. NOTE ** Retain one of the following two sub-paragraphs to
  209.         specify unit width.
  210.         4.  Width:  36 inches (914 mm).
  211.         5.  Width:  42 inches (1066 mm).
  212. NOTE ** Select vinyl finish color in one of the following
  213.         two sub-paragraphs.
  214.         6.  Color:  White, fine-textured finish; paintable.
  215.         7.  Color:  Beige, fine-textured finish.
  216. NOTE ** Retain one of the following two paragraphs.
  217.  
  218.     B.  Fasteners:  Supply non-corroding fasteners; type
  219.         recommended by manufacturer for indicated project
  220.         conditions.
  221.  
  222.     C.  Fasteners:  Supply non-corroding fasteners with tamper-
  223.         resistant heads; type recommended by manufacturer for
  224.         indicated project conditions.
  225.  
  226. PART 3  EXECUTION
  227. NOTE ** Delete the following Article if specifying Lav-
  228.         Shield or Basin Guard only.
  229.  
  230. 3.1 EXAMINATION
  231.  
  232.     A.  Verify the following conditions before installing
  233.         products of this section:  Piping configurations are
  234.         correct type for piping cover component configurations
  235.         specified.
  236.  
  237. 3.2 INSTALLATION
  238.  
  239.     A.  Install products of this section in accordance with
  240.         manufacturer's printed installation instructions.
  241.  
  242. 3.3 PROTECTION OF INSTALLED PRODUCTS
  243.  
  244.     A.  Do not allow damage to installed products by subsequent
  245.         construction activities; protect products until
  246.         Substantial Completion.
  247.  
  248.  
  249.                          END OF SECTION
  250.